Features 水塔及抽水馬達監控記錄
*When you open the app for the first time after downloading and installing it, the screen will appear white and pause for about 30 seconds to configure the database.
Please wait patiently.
You will also be asked to open some permissions such as wifi (GPS) location, or you can go to the permission administrator to open it yourself.
The wifi location permission of this app is turned on because it needs to scan for nearby wifi signals.*After turning on the thinkspeak cloud function, under 5G mobile data, the only functions of the mobile app that can be controlled are the pumping motor switch and forced water replenishment, and the rest are inoperable offline.The main function:1.Double water tower design, parameters can be set to select either water tower or dual water towers for use2.
can control the power on or off of the pumping motor at any time3.
The or switch can force replenishment or stop replenishment at any time.4.
Display the current height (cm) and capacity (liters) of water in the water tower5.
According to the actual water replenishment situation, set the upper and lower float positions of the water tower liquid level switch as a basis for the water level to be too high or too low.6.
Set the flow meter correction factor CT to control the water replenishment accuracy within ±5%, and the flow rate is proportional to the CT value.7.
When in the water replenishing state, you can instantly view the current flow rate/average flow rate/duration time the water flow rate is lower than the set value/how long the motor has been started/AC current value/how much water has been replenished/current real-time display graph8.
Provide real-time notification and records of alarms, making it easy to check whether there are any abnormal messages before and use them as a basis for maintenance.9.
and are used to read the latest data in the controller and update the record.10.
The accuracy of the clock IC is ±0.432 seconds/day.
When the time error is large, you can press one button to reset and synchronize with the mobile phone time.11.
Each replenishment will be recorded in detail and can be queried in order (start time/date/month)12.
Convert SQL and text files to each other.
After converting the motor startup records into text files, you can use a text editor or Excel to process them.
If you uninstall this app, all data records will disappear.
You can copy the files to other directories beforehand.13.
Apply for a Thinkspeak account and set the ID/key to realize the Internet of Things and cloud control of the pumping motor.*Through precise parameter settings, we don’t have to worry about abnormal conditions happening when sleeping, going out, experiencing water outages or earthquakes:1.
If the motor current is abnormal or the water flow is too small for a long time, the motor solid-state relay can be automatically disconnected to shut down the motor.2.
If the automatic water replenishment or forced water replenishment takes too long, the motor solid state relay can be automatically disconnected to turn off the motor.3.
The solid-state relay of the pumping motor is abnormally powered off.
After checking and processing and confirming that it is correct, remember to manually press the to return to the power-on state.
Otherwise, the power line will be in a power-off state, and there will be no automatic water replenishment action afterwards.* When any situation occurs in the water tower and pumping motor, the controller needs to notify us immediately through the mobile phone for processing.
The list of all alarm alarms is as follows:0: Normal, no recording, no notification1: Press the pumping motor switch button to cut off the power to the pumping motor.2: Press the pumping motor switch button to energize the pumping motor3: Press the forced water replenishment button to start the pumping motor.4: Forced water replenishment, the motor continues to run, no recording, no notification5: Press the stop water replenishment button to stop the water pumping motor.6: The forced water replenishment has reached the replenishing level, and the solid state relay switch of the water tower trips, causing the motor to stop.7: The forced water replenishment has lasted for the set time?
minutes, and the solid state relay switch of the water tower tripped, causing the motor to stop.8: Automatic water replenishment starts, the motor starts running, no recording is done9: Automatically replenish water, the motor continues to run, no recording, no notification10: Water replenishment is completed, the motor stops running, and no recording is performed.11: The automatic water replenishment has continued for the set time?
minutes, and the motor solid-state relay switch tripped, causing the motor to stop.12: The water flow rate is too small and the set time has been reached for ?
seconds.
The solid-state relay switch of the motor trips and the motor stops.13: The abnormal current in the motor continues for the set time?
seconds, and the solid-state relay switch of the motor trips, causing the motor to stop.14: Abnormal, the motor solid-state relay switch fails to change from energized to de-energized, this action is invalid; if the motor continues to run, please go to the control box to switch the motor circuit switch from energized to de-energized to stop the motor, and ask a professional to check the motor.
solid state relay circuit15: Abnormal, the motor solid state relay switch fails to change from power off to power on, this action is invalid; if you want to let the motor operate, please go to the control box and switch the three-way switch of the wifi controller from use to not use, and the motor will not be controlled by the controller.
, ask a professional to check the motor solid state relay circuit16: Abnormal, the water tower solid state relay switch failed to change from power off to power on, this action is invalid; forced water replenishment is no longer possible, please ask a professional to check the water tower solid state relay circuit17: Abnormal, the solid-state relay switch of the water tower fails to change from energized to powered off.
This action is invalid; the water cannot be forced to stop.
Please go to the control box to switch the motor circuit switch from energized to powered off to stop the motor.
Please ask a professional to check the solid state of the water tower.
relay circuit18: The water level in water tower 1 has reached the top of the water tower?cm19: The failure position of the float switch of water tower 1 is higher than the replenishing water level?
cm20: The failure position of the liquid level switch in water tower 1 is lower than the replenishing water level?cm21: The water level in water tower 1 has reached 0cm at the bottom of the water tower.22: The water level in water tower 2 has reached the top of the water tower?cm23: The failure position of the float switch in water tower 2 is higher than the replenishing water level?cm24: The failure position of the liquid level switch in water tower 2 is lower than the replenishing water level?cm25: The water level in water tower 2 has reached 0cm at the bottom of the water tower.26: Water flow rate is less than ?L/min27: Note that the solid-state relay of the motor has tripped.
Please make sure that the inspection is normal.
Remember to press the "pumping motor switch" to turn the solid-state relay switch from off to energized.
Otherwise, it will not be able to pump water normally.
It will not be recorded and will be notified every minute.